#!/bin/bash
#
# Copyright (c) 2002-2006,2012-2014 lang-nevyjel@init.at
#
#
# RedHat stuff
# chkconfig: 35 14 86
# description: host-monitoring services
#
### BEGIN INIT INFO
# Provides:      host-monitoring
# Required-Start: $network $syslog logging-server
# Required-Stop: $network $syslog logging-server
# Should-Start: lm_sensors
# Default-Start: 3 5
# Default-Stop: 0 1 2 6
# Description:   start host-monitoring services
### END INIT INFO

export SYSTEMD_NO_WRAP="1"
if [ -f /etc/rc.status ] ; then
    . /etc/rc.status
else
    . /etc/rc.status_suse
fi
. /etc/sysconfig/host-monitoring
. /etc/init.d/ics_tools.sh

HOSTMON_BIN=/opt/cluster/sbin/host-monitoring-zmq.py
SERVER_BIN=/opt/cluster/sbin/collserver.py
PYTHON_BIN=/opt/python-init/bin/python
SERVER_PID=/var/run/collserver/collserver.pid
META_FILE=/var/lib/meta-server/collserver
SERVER_DIRS="/var/run/collserver"

test -x ${HOSTMON_BIN} || exit 5
test -x ${SERVER_BIN} || exit 5
test -x ${PYTHON_BIN} || exit 5

rc_reset

export HOSTNAME=`/bin/hostname`
case "$1" in
    start)     
        echo -n "Starting collserver.py"
        if [ -f ${SERVER_PID} ] ; then
            echo -n " ... already running"
        else
            for dir in $SERVER_DIRS ; do
                [ ! -d "${dir}" ] && mkdir -p ${dir}
            done
            ${SERVER_BIN} ${SERVER_ARGS}
        fi
        rc_status -v
        ;;
    stop)
        echo -n "Stopping collserver.py"
        if [ -f ${SERVER_PID} ] ; then
            if [ -f ${META_FILE} ] ; then
                /opt/cluster/sbin/get_pids_from_meta.py --meta ${META_FILE} --name collserver.py --signal 15
            else        
                kill -s 15 `cat ${SERVER_PID} | head -n 1` || rc_failed
            fi
            if [ -f ${SERVER_PID} ] ; then
                for i in $(seq 40) ; do
                    echo -n "."
                    if [ -x /bin/usleep ] ; then
                        usleep 250000
                    else
                        sleep 1
                    fi
                    [ ! -f ${SERVER_PID} ] && break 
                done
            fi
            [ $i -gt 18 ] && rc_failed || rc_reset
        else
            rc_failed
        fi
        rc_status -v
        ;;
    force-stop)
        echo -n "Force stopping collserver.py"
        if [ -f ${META_FILE} ] ; then
            /opt/cluster/sbin/get_pids_from_meta.py --meta ${META_FILE} --name collserver.py --signal 9
        elif [ -f ${SERVER_PID} ] ; then
            kill -9 `cat ${SERVER_PID} ` || rc_failed
        else
            rc_failed
        fi
        rm -f ${SERVER_PID} ${META_FILE}
        rc_status -v
        ;;
    status)
        echo -n "Checking collserver.py..."
        check_threads_ok ${SERVER_PID} || {
            check_threads ${SERVER_PID} || rc_failed 
        } 
        rc_status -v
        ;;
    restart)
        echo "Restarting $(basename $SERVER_BIN)"
        $0 stop ; sleep 1 ; $0 start || return=$rc_failed
        ;;
    force-restart)
        echo "Restarting $(basename $SERVER_BIN)"
        $0 force-stop ; sleep 1 ; $0 start || return=$rc_failed
        ;;
    *)
        echo "Usage: $0 {start|stop|restart|status|force-stop|force-restart}"
        exit 1
        ;;
esac

rc_exit